Limit Switch Boxes EB300 – VP

Our conductive ATEX limit switch box made of Vestamid, designed for demanding fields of application. Please see our datasheet for detailed information.

Limit switch box EB300-VP2M02-551-ED (Art.-Nr.: 711-VP2M02-551-ED)
• Flexible and conductive vestamid box
• Enclosure IP66 acc. to DIN EN 60529 and DIN EN 60079-0
• Zone 1 and 21 (Ex e und Ex t)
• Cable gland M20x1,5 black (for cable Ø 5,5-13mm)
• Sealings EPDM and NBR, Screws: AISI 304
• Shaft: polyamide PA6
• 2x mechanical Ex d switches Bartec 07-1511-1030, 3-wire N.O / N.C.
• Voltage: 24V DC / 250V AC
• Explosion zone: Zone 1, Zone 21
• ATEX: II 2G Ex de IIC T6 Gb and II 2D Ex t IIIC T80°C Db
• Contacts: silver
• Temp. (min./max.): -20°C to +40°C

Limit switch box EB300-VP2S02-IA (Art.-Nr.: 711-VP2S02-IA)
• Flexible and conductive vestamid box
• Enclosure IP67 acc. to DIN EN 60529
• Zone 1 and 21 (Ex ia)
• Cable gland M20x1,5 blue (for cable Ø 6-12 mm)
• Sealings EPDM and NBR, Screws AISI 304
• Shaft: polyamide PA6
• 2x inductive slot type sensors P+F, SJ3,5-N, 2-wire Ex ia
• Voltage: 8V DC
• Explosion zone: Zone 1, Zone 21
• ATEX: II 2G Ex ia IIC T6 Gb and II 2D Ex ia IIIC T80°C Db
• Temp. (min./max.): -25°C to +70°C